ABS-M30 for Fortus 3D Production Systems

ABS-M30 is up to 25-70 percent stronger than standard Stratasys ABS and is an ideal material for conceptual modeling, functional prototyping, manufacturing tools, and end-use-parts. ABS-M30 has greater tensile, impact, and flexural strength than standard ABS. Layer bonding is significantly stronger than that of standard ABS, for a more durable part. This results in more realistic functional tests and higher quality parts for end use. When combined with a Fortus® 3D Production System, ABS-M30 gives you Real PartsTM that are stronger, smoother, and with better feature detail.

Mechanical Properties1

Test Method

English

Metric

Tensile Strength  (Type 1, 0.125",0.2"/min) ASTM D638 5,200 psi 36 MPa
Tensile Modulus (Type 1, 0.125", 0.2"/min) ASTM D638 350,000 psi 2,400 MPa
Tensile Elongation (Type 1, 0.125", 0.2"/min) ASTM D638 4% 4%
Flexural Strength (Method 1,0.05"/min) ASTM D790 8,800 psi 61 MPa
Flexural Modulus (Method 1, 0.05"/min) ASTM D790 336,000 psi 2,300 MPa
IZOD Impact, notched (Method A, 23°C) ASTM D256 2.6 ft-lb/in 139 J/m
IZOD Impact,un-notched (Method A, 23°C) ASTM D256 5.3 ft-lb/in 283 J/m

 

Thermal Properties2

Test Method

English

Metric

Heat Deflection (HDT) @ 66 psi,  0.125" unannealed ASTM D648 204°F 96°C
Heat Deflection (HDT) @ 264 psi, 0.125" unannealed ASTM D648 180°F 82°C
Vicat Softening Temperature (Rate B/50) ASTM D1525 210°F 99°C
Glass Transition (Tg) DSC (SSYS) 226°F 108°C
Coefficient of Thermal Expansion (flow) ASTM E831 4.9E-05 in/in/°F 8.82E-05 mm/mm/°C
Coefficient of Thermal Expansion (xflow) ASTM E831 4.7E-05 in/in/°F 8.46E-05 mm/mm/°C
Melt Point – – – – – – – – – Not Applicable2 Not Applicable2

Electrical Properties4

 Test Method

Value Range

Volume Resistivity ASTM D257 4.0x10e14 – 5.0x10e13 ohms
Dielectric Constant ASTM D150-98 2.9 – 2.7
Dissipation Factor ASTM D150-98 .0052 – .0049
Dielectric Strength ASTM D149-09, Method A 370 – 71 V/mm
Dielectric Strength IEC 60112 28.0 kV/mm

Other2

 Test Method

Value

Specific Gravity ASTM D792 1,04
Flame Classification UL94 HB (0.06", 1.5 mm)
Rockwell Hardness ASTM D785 109,5

System Availability

Layer Thickness Capability

 Support Structure

 Available Colors

Fortus 360mc
Fortus 400mc
Fortus 900mc
0.013 inch (0.330 mm)
0.010 inch (0.254 mm)
0.007 inch (0.178 mm)
0.005 inch (0.127 mm)5
Soluble Supports Ivory
White
Black
Dark Grey
Red
Blue

The information presented are typical values intended for reference and comparison purposes only. They should not be used for design specifications or quality control purposes. End-use material performance can be impacted (+/-) by, but not limited to, part design, end-use conditions, test conditions, etc. Actual values will vary with build conditions. Tested parts were built on Fortus 400mc @ 0.010″ (0.254 mm) slice. Product specifications are subject to change without notice.

1 Build orientation is on side long edge.
2 Literature value unless otherwise noted.
3 Due to amorphous nature, material does not display a melting point.
4 All electrical property values were generated from the average of test plaques built with default part density (solid). Test plaques were 4.0 x 4.0 x 0.1 inches (102 x 102 x 2.5 mm) and were built both in the flat and vertical orientation. The range
of values is mostly the result of the difference in properties of test plaques built in the flat vs. vertical orientation.
5 0.005 inch (0.127 mm) layer thickness not available for Fortus 900mc.