ULTEM* 9085

ULTEM* 9085 is a flame retardant high performance thermoplastic for direct digital manufacturing and rapid prototyping. It is ideal for the transportation industry due to its high strength-to-weight ratio and its FST (flame, smoke, and toxicity) rating. This unique material’s preexisting certifications make it an excellent choice for the commercial transportation industry – especially aerospace, marine and ground vehicles. Combined with a Fortus® 3D Production System, ULTEM 9085 allows design and manufacturing engineers to produce fully functional parts that are ideal for advanced functional prototypes or end use without the cost or lead time of traditional tooling.

Mechanical Properties1

Test Method

English

Metric

Tensile Strength (Type 1,0.125", 0.2"/min) ASTM D638 10,400 psi 71.6 MPa
Tensile Modulus (Type 1, 0.125", 0.2"/min) ASTM D638 322 kpsi 2,200 MPa
Tensile Elongation (Type 1,0.125", 0.2"/min) ASTM D638 6% 6%
Flexural Strength  (Method 1,0.05"/min) ASTM D790 16,700 psi 115.1 MPa
Flexural Modulus (Method 1, 0.05"/min) ASTM D790 362.6 kpsi 2,500 MPa
IZOD Impact, notched (Method A, 23°C) ASTM D256 2.0 ft-lb/in 106 J/m
IZOD Impact, un-notched (Method A, 23°C) ASTM D256 11.5 ft-lb/in 613.8 J/m

Thermal Properties2

 Test Method

English

Metric

Heat Deflection (HDT)@ 66 psi, 0.125" unannealed ————— ————— —————
Heat Deflection (HDT)@ 264 psi, 0.125" unannealed ASTM D648 307°F 153°C
Glass Transition (Tg) DMA (SSYS) 367°F 186°C
Coefficient of Thermal Expansion ————— ————— —————
Melt Point ————— Not Applicable3 Not  Applicable3

Electrical Properties4

 Test Method

Value Range

Volume Resistivity ASTM D257 1.0 x 10e14 – 6.0 x 10e13 ohms
Dielectric Constant ASTM D150-98 3.2 – 3.0
Dissipation Factor ASTM D150-98 .0027 – .0026
Dielectric Strength ASTM D149-09, Method A 290 – 110 V/mm

Other2

 Test Method

Value

Specific Gravity ASTM D792 1.34
Rockwell Hardness ASTM D785
Flame Classification UL 94
Oxygen Index ASTM D2863 0.49
Vertical Burn FAR 25.853 (Test a (60s), passes at) 2 seconds
FAA Flammability FAR 25.853 (Method A/B) < 5
OSU Total Heat Release (5 min test) FAR 25.853 36 kW/m²
OSU Total Heat Release (2 min test) FAR 25.853 16 kW min/m²

System Availability

Layer Thickness Capability

 Support Structure

 Available Colors

Fortus 400mc
Fortus 900mc
0.013 inch (0.330 mm)5
0.010 inch (0.254 mm)
BASS Tan

The information presented are typical values intended for reference and comparison purposes only. They should not be used for design specifications or quality control purposes. End-use material performance can be impacted (+/-) by, but not limited to, part design, end-use conditions, test conditions, color etc. Actual values will vary with build conditions. Product specifications are subject to change without notice.

1 Build orientation is on side long edge.
2 Literature value unless otherwise noted.
3 Due to amorphous nature, material does not display a melting point.
4 All Electrical Property values were generated from the average of test plaques built with default part density (sparse). Test plaques were 4.0 x 4.0 x 0.1 inches (102 x 102 x 2.5 mm) and were built both in the flat and vertical orientation.
5 Test results based on Stress Crack Resistance (24-hour immersion @ 23°C and @ 100°C).