ABSplus™ – P430 for Fortus 3D Production Systems (Traduction en cours)
Stratasys ABSplus-P430 is a true production-grade thermoplastic and is an ideal material for conceptual modeling, functional prototyping, manufacturing tools, and end-use-parts. The marriage of ABSplus-P430 with Fortus 3D Production Systems gives you the ability to create real parts directly from digital files that are stronger, smoother and with high feature detail.
Mechanical Properties1 |
Test Method |
English |
Metric |
Tensile Strength (Type 1, 0.125″, 0.2″/min) | ASTM D638 | 5,300 psi | 37 MPa |
Tensile Modulus (Type 1, 0.125″, 0.2″/min) | ASTM D638 | 330,000 psi | 2,320 MPa |
Tensile Elongation (Type 1, 0.125″, 0.2″/min) | ASTM D638 | 3% | 3% |
Flexural Delamination | ASTM D790 | 4,500 psi | 31 MPa |
Flexural Strength (Method 1, 0.05″/min) | ASTM D790 | 7,600 psi | 53 MPa |
Flexural Modulus (Method 1, 0.05″/min) | ASTM D790 | 320,000 psi | 2,250 MPa |
IZOD Impact, notched (Method A, 23°C) | ASTM D256 | 2.0 ft-lb/in | 106 J/m |
Thermal Properties2 |
Test Method |
English |
Metric |
Heat Deflection (HDT) @ 66 psi | ASTM D648 | 204°F | 96°C |
Heat Deflection (HDT) @ 264 psi | ASTM D648 | 180°F | 82°C |
Coefficient of Thermal Expansion | ASTM E831 | 4.90 E -05 in/in/°F | – – – – – |
Melt Point | – – – – – – – – – | Not Applicable3 | Not Applicable3 |
Electrical Properties4 |
Test Method |
Value Range |
Volume Resistivity | ASTM D257 | 3.0x10e14 – 6.0x10e13 ohms |
Dielectric Constant | ASTM D150-98 | 2.9 – 2.6 |
Dissipation Factor | ASTM D150-98 | .0053 – .0046 |
Dielectric Strength | ASTM D149-09, Method A | 320 – 100 V/mm |
Dielectric Strength | IEC 60112 | 28.0 kV/mm |
Other2 |
Test Method |
Value |
Specific Gravity | ASTM D792 | 1.04 |
System Availability |
Layer Thickness Capability |
Support Structure |
Available Colors |
Fortus 250mc | 0.013 inch (0.330 mm) 0.010 inch (0.254 mm) 0.007 inch (0.178 mm)5 |
Soluble Supports | Ivory White Black Dark Grey Red Blue Olive Green Nectarine Fluorescent Yellow Custom Colors |
The information presented are typical values intended for reference and comparison purposes only. They should not be used for design specifications or quality control purposes. End-use material performance can be impacted (+/-) by, but not limited to, part design, end-use conditions, test conditions, color etc. Actual values will vary with build conditions. Product specifications are subject to change without notice.
1 Build orientation is on side long edge.
2 Literature value unless otherwise noted.
3 Due to amorphous nature, material does not display a melting point.
4 All Electrical Property values were generated from the average of test plaques built with default part density (sparse). Test plaques were 4.0 x 4.0 x 0.1 inches (102 x 102 x 2.5 mm) and were built both in the flat and vertical orientation.